2. Settheweightingandresponse(see“Setting the
Weighting”and“Setting the Response Time”onPage5).
3. Pointthemeter’smicrophoneatthesoundsource.The
meterdisplaysthecontinuousaveragesoundlevel
duringaone-secondsamplingperiodandupdatesthe
numberonthedisplayonceasecond.
4. Afterthemeasurement,setRANGEtoOFF.
Taking Maximum Measurements
1.
FollowSteps1-3in“Continuous Average Measurements”.
2. PressMAX;thewordMAX appears.
Themeterdisplaysonlytheloudestmeasuredsound
levelduringtheone-secondsamplingperiod.The
bargraphshowsthemaximumlevelevery0.2or0.5
seconds.
Thebargraphsegmentthatcorrespondstothepeak
readingstaysonthedisplayfor2secondsoruntilthe
metermeasuresahighermaximumlevel.
3. PressMAXagaintocancelthecontinuousmaximum
measurement.Acontinuousaveragemeasurement
resumes.
Integrated Average Measurements
Followthesestepstomonitorthesoundlevelandaverage
themeasurementoveraperiodof1to199seconds.The
meterstorestheaverage,maximum,andminimumsound
levelsduringthesettime.